Smoke extractors Ventilyacionnoe oborudovanie CC-HT, FV-HT, PR-Q HT, etc.

CC-HT series ducted axial fans are a series of high-performance axial fans designed and certified for high-temperature smoke extraction. The fans are suitable for operation at a temperature of +60 °C.
CC-HT. Technical specifications (eng).
The CC-SHT series high-efficiency ducted axial fans are a series of high-performance axial fans designed and certified for high-temperature smoke extraction. The fans are suitable for operation at a temperature of +60 °C.
CC-SHT. Technical specifications (eng).
Smoke-removing centrifugal roof fans of the FC-HT series are suitable for high-temperature smoke extraction. The series is suitable for operation at a temperature of +80°C.
FC-HT. Technical specifications (eng).
Smoke-removing centrifugal roof fans of the TC-HT series are designed for direct ventilation of rooms or by means of air ducts and are used for extraction of high-temperature smoke. A special feature of the series is the vertical exhaust conveyor, which guarantees fast and efficient removal of toxic fumes. The series is suitable for operation at a temperature of +150°C.
TC-HT. Technical specifications (eng).
Smoke-removing centrifugal bladed fans of the PR-Q HT series are a series of inversely curved centrifugal fans designed for high-temperature smoke extraction. The series is suitable for removing smoke at temperatures up to +100°C.
PR-Q HT. Technical specifications (eng).
The BOX-T HT series smoke-removing box fans with a double inlet are designed for installations requiring rapid smoke removal. They are suitable for transporting clean air and non-dusty fumes up to a maximum temperature of +200°C during continuous use or in case of an emergency at temperatures up to +400°C for 120 minutes.
BOX-T HT. Technical specifications (eng).
SVP series fire protection units are passive fire protection devices installed in the ventilation system, the purpose of which is to minimize the impact of fire and ensure the safety of people. The SVP consists of a control panel, a pressure unit (fan) and a pressure sensor (remote or integrated).
SVP. Technical specifications (eng).
Fire-resistant air ducts of the REIDUCT-Q and REIDUCT-C series are channels and connectors made of metal to ensure an ideal connection between the pressure unit (fan) and the air intake elements. They complement the fire-fighting installations of the SVP series.
REIDUCT-Q. Technical specifications (eng).
REIDUCT-C. Technical specifications (eng).
ACS control panels and carbon monoxide sensors are industrial gas detectors for the indication of CO, gasoline vapors and other gases and automatic control of smoke removal systems.
ACS. Technical specifications (eng).
Ventilation smoke removal systems for closed car parks are axial and centrifugal pulse fans designed for installation in underground parking lots or tunnels, specially designed and certified to remove smoke and flammable gases in the event of a fire.
Models:JET FANS CC JD LP. Technical specifications (eng).
JET FANS CC JD. Technical specifications (eng).
CC-JC. Technical specifications (eng).
The CC-SHT series high-efficiency ducted axial fans are a series of high-performance axial fans designed and certified for high-temperature smoke extraction. The fans are suitable for operation at a temperature of +60 °C.
Smoke-removing centrifugal roof fans of the FC-HT series are suitable for high-temperature smoke extraction. The series is suitable for operation at a temperature of +80°C.
Smoke-removing centrifugal roof fans of the TC-HT series are designed for direct ventilation of rooms or by means of air ducts and are used for extraction of high-temperature smoke. A special feature of the series is the vertical exhaust conveyor, which guarantees fast and efficient removal of toxic fumes. The series is suitable for operation at a temperature of +150°C.
Smoke-removing centrifugal bladed fans of the PR-Q HT series are a series of inversely curved centrifugal fans designed for high-temperature smoke extraction. The series is suitable for removing smoke at temperatures up to +100°C.
The BOX-T HT series smoke-removing box fans with a double inlet are designed for installations requiring rapid smoke removal. They are suitable for transporting clean air and non-dusty fumes up to a maximum temperature of +200°C during continuous use or in case of an emergency at temperatures up to +400°C for 120 minutes.
SVP series fire protection units are passive fire protection devices installed in the ventilation system, the purpose of which is to minimize the impact of fire and ensure the safety of people. The SVP consists of a control panel, a pressure unit (fan) and a pressure sensor (remote or integrated).
Fire-resistant air ducts of the REIDUCT-Q and REIDUCT-C series are channels and connectors made of metal to ensure an ideal connection between the pressure unit (fan) and the air intake elements. They complement the fire-fighting installations of the SVP series.
ACS control panels and carbon monoxide sensors are industrial gas detectors for the indication of CO, gasoline vapors and other gases and automatic control of smoke removal systems.
Ventilation smoke removal systems for closed car parks are axial and centrifugal pulse fans designed for installation in underground parking lots or tunnels, specially designed and certified to remove smoke and flammable gases in the event of a fire.
Models:
All Ventilyacionnoe oborudovanie products
The group "New Technologies" offers for review the products of the plant Ventilyacionnoe oborudovanie: fans: centrifugal roof, axial roof, wall and round axial, channel axial, radial centrifugal of small diameter, centrifugal vane reverse-bent, channel centrifugal, box-shaped with direct drive, centrifugal box-shaped, explosion-proof design, smoke-removing, anti-corrosion, high-temperature, heat recovery units, accessories
About Ventilyacionnoe oborudovanie
For many years, the Italian company has been developing and producing a new high-tech range of ventilation products that have found application in all areas of civil and industrial construction.
-
LEADERSHIP
Today, the company is a well-known international company – one of the leaders of the global industrial industry, using the most advanced technologies. -
quality
The manufacturer guarantees its customers the quality of its products. The quality system complies with all European and international standards, such as CE or ISO 9001:2000. -
VERSATILITY
Having the advantage of the versatility of the product line, the company has focused its efforts on strengthening its position in the European and global markets.
NEW TECHNOLOGIES GROUP
For sales and support please contact
Contact us or your local dealer for more information on certifications, features, reviews, pricing, stock availability and delivery terms for Ventilyacionnoe oborudovanie products.
Reply guaranteed within 8 business hours
- (727)345-47-04
- (3955)60-70-56
- (8182)63-90-72
- (8512)99-46-04
- (3852)73-04-60
- (4722)40-23-64
- (4162)22-76-07
- (4832)59-03-52
- (8352)28-53-07
- (351)202-03-61
- (8202)49-02-64
- (3022)38-34-83
- (395)279-98-46
- (4932)77-34-06
- (3412)26-03-58
- (4012)72-03-81
- (4842)92-23-67
- (843)206-01-48
- (3842)65-04-62
- (4212)92-98-04
- (8332)68-02-04
- (4966)23-41-49
- (4942)77-07-48
- (861)203-40-90
- (391)204-63-61
- (3522)50-90-47
- (4712)77-13-04
- (4742)52-20-81
- (3519)55-03-13
- (375)257-127-884
- (495)268-04-70
- (8152)59-64-93
- (8552)20-53-41
- (831)429-08-12
- (3843)20-46-81
- (383)227-86-73
- (3496)41-32-12
- (3812)21-46-40
- (4862)44-53-42
- (3532)37-68-04
- (8412)22-31-16
- (342)205-81-47
- (8142)55-98-37
- (8112)59-10-37
- (863)308-18-15
- (4912)46-61-64
- (812)309-46-40
- (846)206-03-16
- (8342)22-96-24
- (845)249-38-78
- (8692)22-31-93
- (3652)67-13-56
- (4812)29-41-54
- (862)225-72-31
- (8652)20-65-13
- (3462)77-98-35
- (8212)25-95-17
- (4752)50-40-97
- (998)71-205-18-59
- (8482)63-91-07
- (3822)98-41-53
- (4872)33-79-87
- (4822)63-31-35
- (3452)66-21-18
- (347)229-48-12
- (3012)59-97-51
- (8422)24-23-59
- (8672)28-90-48
- (4922)49-43-18
- (423)249-28-31
- (844)278-03-48
- (8172)26-41-59
- (473)204-51-73
- (4112)23-90-97
- (4852)69-52-93
- (343)384-55-89
Send your question now: